Incidence and Predictors of Repeat Bone Mineral Densitometry: A Longitudinal Cohort Study.

TitleIncidence and Predictors of Repeat Bone Mineral Densitometry: A Longitudinal Cohort Study.
Publication TypeJournal Article
Year of Publication2017
AuthorsVanGompel ECWhite, Franks P, Robbins JA, Fenton JJ
JournalJ Gen Intern Med
Volume32
Issue10
Pagination1090-1096
Date Published2017 Oct
ISSN1525-1497
Abstract

BACKGROUND: Existing guidelines for repeat screening and treatment monitoring intervals regarding the use of dual-energy x-ray absorptiometry (DXA) scans are conflicting or lacking. The Choosing Wisely campaign recommends against repeating DXA scans within 2 years of initial screening. It is unclear how frequently physicians order repeat scans and what clinical factors contribute to their use.

OBJECTIVE: To estimate cumulative incidence and predictors of repeat DXA for screening or treatment monitoring in a regional health system.

DESIGN: Retrospective longitudinal cohort study PARTICIPANTS: A total of 5992 women aged 40-84 years who received initial DXA screening from 2006 to 2011 within a regional health system in Sacramento, CA.

MAIN MEASURES: Two- and five-year cumulative incidence and hazard rations (HR) of repeat DXA by initial screening result (classified into three groups: low or high risk of progression to osteoporosis, or osteoporosis) and whether women were prescribed osteoporosis drugs after initial DXA.

KEY RESULTS: Among women not treated after initial DXA, 2-year cumulative incidence for low-risk, high-risk, and osteoporotic women was 8.0%, 13.8%, and 19.6%, respectively, increasing to 42.9%, 60.4%, and 57.4% by 5 years after initial screening. For treated women, median time to repeat DXA was over 3 years for all groups. Relative to women with low-risk initial DXA, high-risk initial DXA significantly predicted repeat screening for untreated women [adjusted HR 1.67 (95% CI 1.40-2.00)] but not within the treated group [HR 1.09 (95% CI 0.91-1.30)].

CONCLUSIONS: Repeat DXA screening was common in women both at low and high risk of progression to osteoporosis, with a substantial proportion of women receiving repeat scans within 2 years of initial screening. Conversely, only 60% of those at high-risk of progression to osteoporosis were re-screened within 5 years. Interventions are needed to help clinicians make higher-value decisions regarding repeat use of DXA scans.

DOI10.1007/s11606-017-4094-y
Alternate JournalJ Gen Intern Med
PubMed ID28634907
PubMed Central IDPMC5602758